Produkty dla flr mr176 (17)

FLRY-B FB600

FLRY-B FB600

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB600 CROSS SECTION (Cu):6,00 mm² STRANDED COPPER CONDUCTER (Cu):84x0,29 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 4,15 MIN. WALL THICKNESS (mm):0,32 APPROXIMATE WEIGHT (kg/km):61,00 CONDUCTOR RESISTANCE:<3,14 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
VIPROFF - VIPROOF

VIPROFF - VIPROOF

Specifications Aluminium extruded body with electrostatic powder coated Electrostatic powder coated aluminium die cast end caps Mid Power LED light source LED (L80/B10) + DRIVER life time more than 50.000 Hours Tempered (clear and frosted) glass cover with IK10 grade High efficient PMMA, Opal, semi-transparent or transparent diffuser option Input Voltage: 198-264V AC, 176-280V DC, 50-60 Hz Operating Temperature (Ta): -400C / +700C Applications Zone 2 - Zone 22 applications Industrial Facilities Oil Rafineries Gas Stations Petrochemical Facilities
DN 125 - DN 100

DN 125 - DN 100

OEM Spare Parts for Concrete Pumps
FLRY-B FB150

FLRY-B FB150

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB150 CROSS SECTION (Cu):1,50 mm² STRANDED COPPER CONDUCTER (Cu):30x0,24 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,30 MIN. WALL THICKNESS (mm):0,24 APPROXIMATE WEIGHT (kg/km):16,00 CONDUCTOR RESISTANCE:<12,7 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB5000

FLRY-B FB5000

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB5000 CROSS SECTION (Cu):50,00 mm² STRANDED COPPER CONDUCTER (Cu):396x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 11,60 MIN. WALL THICKNESS (mm):0,6 APPROXIMATE WEIGHT (kg/km):482,30 CONDUCTOR RESISTANCE:<0,368 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB050

FLRY-B FB050

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB050 CROSS SECTION (Cu):0,50 mm² STRANDED COPPER CONDUCTER (Cu):16x0,19 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 1,50 MIN. WALL THICKNESS (mm):0,22 APPROXIMATE WEIGHT (kg/km):7,00 CONDUCTOR RESISTANCE:<37,1 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB250

FLRY-B FB250

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB250 CROSS SECTION (Cu):2,50 mm² STRANDED COPPER CONDUCTER (Cu):50x0,24 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,85 MIN. WALL THICKNESS (mm):0,28 APPROXIMATE WEIGHT (kg/km):26,00 CONDUCTOR RESISTANCE:<7,6 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB1000

FLRY-B FB1000

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB1000 CROSS SECTION (Cu):10,00 mm² STRANDED COPPER CONDUCTER (Cu):80x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B AND CLASS C) 5,75 MIN. WALL THICKNESS (mm):0,48 APPROXIMATE WEIGHT (kg/km):108,00 CONDUCTOR RESISTANCE:<1,82 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB300

FLRY-B FB300

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB300 CROSS SECTION (Cu):3,00 mm² STRANDED COPPER CONDUCTER (Cu):44x0,29 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 3,25 MIN. WALL THICKNESS (mm):0,32 APPROXIMATE WEIGHT (kg/km):34,00 CONDUCTOR RESISTANCE:<6,15 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB200

FLRY-B FB200

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB200 CROSS SECTION (Cu):2,00 mm² STRANDED COPPER CONDUCTER (Cu):28x0,29 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,65 MIN. WALL THICKNESS (mm):0,28 APPROXIMATE WEIGHT (kg/km):23,00 CONDUCTOR RESISTANCE:<9,42 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-A FA150

FLRY-A FA150

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FA150 CROSS SECTION (Cu):1,50 mm² STRANDED COPPER CONDUCTER (Cu):19x0,32 mm INSULATION MATERIAL AND DIAMETER(mm ±0,03):PVC (according to ISO 6722-1, CLASS B and CLASS C) 2,4 WALL THICKNESS min (mm):0,20 APPROXIMATE WEIGHT (kg/km):16,00 CONDUCTOR RESISTANCE:<12,7 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B F075

FLRY-B F075

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:F075 CROSS SECTION (Cu):0,75 mm² STRANDED COPPER CONDUCTER (Cu):24x0,19 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 1,80 MIN. WALL THICKNESS (mm):0,24 APPROXIMATE WEIGHT (kg/km):9,00 CONDUCTOR RESISTANCE:<24,7 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB400

FLRY-B FB400

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB400 CROSS SECTION (Cu):4,00 mm² STRANDED COPPER CONDUCTER (Cu):56x0,29 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 3,55 MIN. WALL THICKNESS (mm):0,32 APPROXIMATE WEIGHT (kg/km):42,00 CONDUCTOR RESISTANCE:<4,71 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-A FA250

FLRY-A FA250

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FA250 CROSS SECTION (Cu):2,50 mm² STRANDED COPPER CONDUCTER (Cu):19x0,41, mm INSULATION MATERIAL AND DIAMETER(mm ±0,03):PVC (according to ISO 6722-1, CLASS B and CLASS C) 3,0 WALL THICKNESS min (mm):0,28 APPROXIMATE WEIGHT (kg/km):26,00 CONDUCTOR RESISTANCE:<7,6 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB3500

FLRY-B FB3500

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB3500 CROSS SECTION (Cu):35,00 mm² STRANDED COPPER CONDUCTER (Cu):276x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 9,90 MIN. WALL THICKNESS (mm):0,56 APPROXIMATE WEIGHT (kg/km):371,00 CONDUCTOR RESISTANCE:<0,527 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB100

FLRY-B FB100

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB100 CROSS SECTION (Cu):1,00 mm² STRANDED COPPER CONDUCTER (Cu):32x0,19 mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,00 MIN. WALL THICKNESS (mm):0,24 APPROXIMATE WEIGHT (kg/km):11,00 CONDUCTOR RESISTANCE:<18,1 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)
FLRY-B FB1600

FLRY-B FB1600

Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles. PRODUCT CODE:FB1600 CROSS SECTION (Cu):16,00 mm² STRANDED COPPER CONDUCTER (Cu):126x0,39mm INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 6,80 MIN. WALL THICKNESS (mm):0,52 APPROXIMATE WEIGHT (kg/km):170,00 CONDUCTOR RESISTANCE:<1,16 Ω/km WORKING TEMPERATURE:-40 to +105°C (CLASS B)